T-Series

IMPEDANCE AUTO MATCHING NETWORK

 

FEATURES

l         Auto Matching Networks covering 100KHz-100MHz

l         Fast Initial Matching (about 2sec. Or less)

l         Fast Continuous Matching (instantaneous)

l         Precise Resolution (about 1% or less REF Power)

l         Auto Preset

l         Custom Designs Available

 

APPLICATION

l         Plasma Etching

l         RIE

l         Plasma CVD

l         RF Sputtering

l         Bias Power Supply

l         Ion Implanting

l         R&D Applications

 

General

The impedance matching networks are used to maximize power transfer between the RF generator and plasma discharge load for plasmas processing systems.

The plasma impedance can vary over a wide range depending upon a variety of parameters, including electrode construction, gas pressure, gas flow rate, kinds of gas, and RF power.

 

The “T-series” auto matching networks have an extremely wide tuning range to handle the multi process requirements of today, usually without component changes. Should extra capacitance or inductance be required, ample space has been provided.

 

Modern semiconductor processes require high speed tuning and resolution. To respond to these requirements, “T-series” auto matching networks are typically able to match in 2 seconds or less with a maximum reflected power of 1 percent to forward power.

 

RF AND LF MATCHING NETWORKS

Today’s semiconductor systems can require the use not only one 13.56MHz supply, but also lower or higher frequencies in tandem. Often it is required to mix frequencies for delicate processes. To respond to these needs, we can provide auto matching networks covering 100KHz to 100MHz. The lower frequency units cover a wide frequency range and can be used for production line systems as well as R&D.

 

BUILT-IN/SEPARATE CONTROLLER

The “T-series” matching networks are broken into three families. One uses a separate controller, model RC-11, and the others use two different built-in controllers.

 

RC-11 Separate Controller

Should the user require an external controller, the “T-series” matching network can be supplied with an RC-11 controller. The controller can be installed at a remote location, such as in a system control rack, for easy access by the operator. Also the size of the matching network can be reduced, since the controller is external.

The RC-11 controller is provided with tune/load position indicators, status indicators, controls and analog remote signals necessary for system control.

 

Built-in Controller

Should the user require a built-in controller, the matching network can be supplied with a built-in controller “A” or “B”. The built-in controller types require installation space only for the single box.

 

Built-in Controller Type A

The matching network which has model number with suffix “A” ( ex. ATL-100RA) is supplied with a built-in controller “A”. This matching network can be provided with status indicators on the front panel and analog remote signals necessary for system control but does not have manual control switches and tune/load position indicators. If the customer needs these controls and indicators, we can supply an optional MC-1 manual controller.

 

Built-in Controller Type B

The matching network which has model number with suffix “B” (ex. TH-10B) is supplied with a built-in controller “B”. This matching network can be provided with almost same tune/load position indicators, status indicators, controls and analog remote signals as RC-11.

 

CONTROL CIRCUITRY

The features of the Control Circuit:

1.    The matching network uses a pulsed voltage servo motor driving  circuit, which supplies pulsed voltages to the servo motor. The pulse width is controlled by the TUNE or LOAD error signals. This provides extremely high speed matching with precise resolution. The life of the servo motor is enhanced since there is a constant voltage supplied to the motors.

2.    The unit also uses brake circuitry, which brakes the servo motor when TUNE or LOAD is just passing the matching position. This feature prevents oscillation of the TUNE and LOAD motors and stops them at the matching position.

3.    The matching network incorporates an extremely precise sensor circuitry which is controlled by the RF power level. This enables the unit to operate with high resolution over a wider dynamic range of RF power.

4.    *The unit will automatically preset the TUNE and LOAD positions by detecting AC power on, RF Power off, or TUNE and LOAD, reaching thee limits at the same time. This results in hands off operation. This function can be disabled by simply changing jumper plugs.

5.    *TUNE and LOAD position meters are available, which permits easy reading of positions without opening the unit.

6.    *LEDs are used to indicate phase (lead/lag) and magnitude (high/low). Should the network be unable to find a match point, these LEDs will remain lit. This gives the operator visual indications of the matching condition.

7.    LEDs are also provided for TUNE and LOAD limits.

 

Note: The functions marked with * are not provided with the matching networks with built-in controller type A.

 

CUSTOM DESIGN MATCHING NETWORK

Besides offering a complete line of standard matching networks, we can also provide custom specific matching networks. Please feel free to consult our factory for your needs.

 

OPTIONAL ITEMS

l         Phase Shift Controller –2,3 or 4 channel output w/ phase-locked loop

l         Phase Shift Controller – one channel output w/o phase –locked loop

l         DC Bias Voltage Probes

l         RF Voltage Probes

l         Matching transformers for 50-300KHz @1KW and 300KHz-1MHz @1KW

l         Isolation transformers for 50-400KHz @1KW and 400KHz-2MHz @1KW

 

High Frequency Auto Matching Network w/ Separate Controller RC-11

Model

Frequency

RF Power

Plasma Resistance

Controller

Cooling

Size (WXDXH mm)

TH-5R

13.56MHz

500W

<50 Ohms

RC-11

Air

180X300X145

TH-10R

13.56MHz

1KW

<50 Ohms

RC-11

Air

255X374X175

TH-15R

13.56MHz

1.5KW

<50 Ohms

RC-11

Air

255X374X175

TH-20RS

13.56MHz

2KW

<50 Ohms

RC-11

Air

320X420X175

TH-20R

13.56MHz

2KW

<50 Ohms

RC-11

Air and Water

240X340X150

TH-30R-1 (1000pf Load)

13.56MHz

3KW

<50 Ohms

RC-11

Air and Water

240X450X150

TH-30R-2

(2000pf Load)

13.56MHz

3KW

<50 Ohms

RC-11

Air and Water

240X450X150

TH-50R-1

(1000pf Load)

13.56MHz

5KW

<50 Ohms

RC-11

Air and Water

240X450X150

TH-50R-2

(2000pf Load)

13.56MHz

5KW

<50 Ohms

RC-11

Air and Water

240X450X150

TH-150R

13.56MHz

15KW

<50 Ohms

RC-11

Air and Water

380X550X220

TV-5R

27-100MHz

500W

<50 Ohms

RC-11

Air

220X285X145

TV-10R

27-100MHz

1KW

<50 Ohms

RC-11

Air

285X350X150

TV-20R

27-100MHz

2KW

<50 Ohms

RC-11

Air and Water

240X450X150

 

High Frequency Auto Matching Network w/ Built-in Controller Type B

TH-10B

13.56MHz

1KW

<50 Ohms

Type B

Air

310X400X175

TH-15B

13.56MHz

1.5KW

<50 Ohms

Type B

Air

310X400X175

TH-20B

13.56MHz

2KW

<50 Ohms

Type B

Air and Water

240X400X205

TH-30B

13.56MHz

3KW

<50 Ohms

Type B

Air and Water

230X330X170

TH-30BII

13.56MHz

3KW

<50 Ohms

Type B

Air and Water

240X400X205

TH-50B

13.56MHz

5KW

<50 Ohms

Type B

Air and Water

240X400X205

TV-10B

27-100MHz

1KW

<50 Ohms

Type B

Air and Water

310X400X175

TV-20B

27-100MHz

2KW

<50 Ohms

Type B

Air

240X400X205

TV-20BJ

27.12MHz

2KW

<50 Ohms ICP

Type B

Air

200X380X240

 

Low Frequency Auto Matching Network w/ Separate Controller RC-11

TK-10R

100-300KHz

1KW

>50 Ohms

RC-11

Air

300X300X300

TK-15R

100-300KHz

1.5KW

>50 Ohms

RC-11

Air

240X380X260

TK-30R

100-300KHz

3KW

>50 Ohms

RC-11

Air

330X380X340

TL-2R

0.3-1MHz

200W

>50 Ohms

RC-11

Air

240X260X165

TL-10R

0.3-1MHz

1KW

>50 Ohms

RC-11

Air

305X300X200

TL-10RL

0.3-1MHz

1KW

<50 Ohms

RC-11

Air

270X430X220

TL-15R

0.3-1MHz

1.5KW

>50 Ohms

RC-11

Air

230X390X200

TL-30R

0.3-1MHz

3KW

>50 Ohms

RC-11

Air

330X350X180

TM-2R

1-3MHz

200W

>50 Ohms

RC-11

Air

240X260X165

TM-10R

1-3MHz

1KW

>50 Ohms

RC-11

Air

300X350x200

TM-10RL

1-3MHz

1KW

<50 Ohms

RC-11

Air

300X350X200

TM-20RL

1-3MHz

2KW

<50 Ohms

RC-11

Air

370X420X200

 

Low Frequency Auto Matching Network w/ Built-in Controller Type A

TK-5RA

100-300KHz

500W

>50 Ohms

Type A

Air

285X380X200

ATL-100RA

0.3-1MHz

1000W

>50 Ohms

Type A

Air

210X450X200

TL-15RA

0.3-1MHz

1.5KW

>50 Ohms

Type A

Air

230X390X200

 

 

 

 

AT SERIES AUTO MATCHING NETWORK

Addition to the “T-series” auto matching networks, we have “AT-Series” auto matching networks in our standard production lines. This series networks are provided with the manual control switches and indicators necessary for operation installed in one box. They do not have a tune/load position indicator and analog signal interface for system, however. They are provided with lower price than “T-series” matching networks.

 

AT-Series Auto Matching Network w/ Built-in Controller Type AT

Model

Frequency

RF Power

Plasma Resistance

Controller

Cooling

Size (WXDXH mm)

ATH-50

13.56MHz

500W

<50 Ohms

Type AT

Air

228X380X160

ATH-100

13.56MHz

1KW

<50 Ohms

Type AT

Air

355X350X200

                                                                                                                                               

MANUAL MATCHING NETWORK

We have the manual matching networks in our standard production line. They are mainly used for small production systems or research and development.

 

Manual Matching Network

MTK-100

100-300KHz

1KW

>50 Ohms

N.A

Air

430X320X360

MTL-100

0.3-1MHz

1KW

>50 Ohms

N.A

Air

410X390X250

MTM-100

1-3MHz

1KW

>50 Ohms

N.A

Air

460X410X280

MTH-50

13.56MHz

500W

<50 Ohms

N.A

Air

285X210X155

MTH-100

13.56MHz

1KW

<50 Ohms

N.A

Air

355X350X200

MTV-10

27-40MHz

1KW

<50 Ohms

N.A

Air

285X350X150

 

PHASE SHIFT CONTROLLER

We have the manual phase shift controller and auto phase shift controller in our standard production lines.

 

The manual phase shift controller shifts the phase of input signal from a master generator and delivers to a slave generator. The phase can be shifted by a potentiometer on the front panel from 0 to 360 degrees. This can be used in the systems which do not require phase-locked loop.

 

The auto phase shift controller automatically shifts the phase of the signal to the slave generator till the phase difference between the signal picked up at the reference electrode and one picked up at the slave electrode coincide with the setpoint given by a potentiometer on the front panel or remote analog signal. The phase can be shifted -180 - 0 - +180 degrees. This can be used in the systems which require phase-locked loop. The auto phase shift controller has a digital phase meter to indicate the phase difference.

 

Phase Shift Controller

Model

Frequency

Auto/Manual

Input

Output

Phase Meter

Size (WXDXH mm)

PSC-1

13.56-60MHz

Manual

1

1

None

150X254X70

PC-1A

13.56-60MHz

Manual

1

1

1

265X325X99

PSC-2

13.56-60MHz

Auto

2

2

1

265X325X99

PSC-3

13.56-60MHz

Auto

3

3

2

480X305X99

PSC-4

13.56-60MHz

Auto

4

4

3

480X305X99